CDR-9211-2M1

CDR-9211-2M1

920W

Dual Input (AC/DC-DC)

Redundant

Type
  • Dual Input (AC/DC-DC)
Dimensions
  • 346 X 76 X 40 mm (D x W x H)
Max Power
  • 920W
80 PLUS
  • 80 plus Platinum
Key Features
  • 80 PLUS Platinum
  • N+1 Redundant
  • Support PMBus 1.2
  • Active Power Factor Correction
  • Black Box Recorder
  • Cold Redundancy
  • Smart Ride Through
  • Closed Loop System Protection (CLST)
  • Internal ORing
Datasheet
Input
Voltage AC input 90 - 264Vac
DC input 180 - 300Vdc
Frequency 47 - 63Hz
Current 100 - 240Vac / 11.4 - 3.9A
200 - 240Vdc / 5.6 - 3.4A
Output
Voltage+12V+5Vsb
Regulation±5%±5%
Max Load75A(100-240Vac/ 200-240Vdc)4.0A
Ripple & Noise120mVp-p50mVp-p
General
Hold-up time 11 ms @ 75% load
Efficiency At least 94% @ 50% load
MTBF 400,000 hours at 30°C
Environmental
Temperature Operating: 0 to 55°C
Non-operating: -40 to 70°C ambient
Altitude Operating: 16,500 feet (5,000 meters)
Non-operating: 35,000 feet (10,580 meters)
Relative humidity Operating: 5% to 90% RH, non-condensing
Non-operating: 5% to 95% RH, non-condensing
UL, cUL, TUV, BSMI, CCC, CB, CE, FCC Class A, CISPR Class A, RoHS